Beijing Huadu Bora Building Boards Co.,Ltd.
HDRP-1000SM with Outside of SBS or PVC and Inside of Metal Covering for Waterproof
Maximum Span and Thermal Coefficient
|
Thickness of Panel mm |
Thermal Conductivity of Panel w/mk |
Thickness of Covering
mm
|
Weight of Panel kg/m2 |
|
50 |
0.43 |
0.6 |
8.01 |
2.85 2.55 2.35 2.10 1.80 |
3.40 3.10 2.90 2.70 2.40 |
0.8 |
9.97 |
3.05 2.75 2.55 2.30 2.00 |
3.70 3.40 3.10 2.90 2.60 |
1.0 |
11.93 |
3.25 2.95 2.75 2.50 2.20 |
3.90 3.60 3.30 3.10 2.80 |
80 |
0.23 |
0.6 |
8.76 |
2.95 2.65 2.45 2.20 1.90 |
3.60 3.30 3.10 2.90 2.60 |
0.8 |
10.72 |
3.15 2.85 2.65 2.40 2.10 |
3.90 3.60 3.30 3.10 2.80 |
1.0 |
12.68 |
3.35 3.05 2.85 2.60 2.30 |
4.10 3.80 3.50 3.30 3.00 |
|
|
Huadu advise you, should deem if necessary, to request more detailed instructions. Huadu reserves the right to modify their porducts at any time without prior warning.
♦ Structure of Roof Panel
1.Outside of SBS or PVC Covering
2.Welding in the joint connection of SBS or PVC
3.PUR Sandwich Panel with inside of metal covering
4.Purlin
A strap of SBS/PVC is covered in the joint of panels for the first layer of waterproofing. In order to show the good presentation and strengthen the effect of waterproofing, a sheet of SBS/PVC with fine mineral facing is covered as the top layer. This kind of panel is suitable to the roof which has soft slope, large span and high standard of waterproofing.
♦ Projects
►More